product description:
Compared with traditional oil-immersed light-duty test transformers, this series of gas-filled power frequency test transformers has a weight reduction of 20%-60% (depending on the voltage and capacity level), and no oil pollution, single test The voltage level of the transformer can reach 300KV. Due to the new production technology, the technical performance of the product has been greatly improved, and it is especially suitable for on-site work and frequent moving working conditions.
Product parameter
Model parameter correspondence table
Specification RCDQ |
apacity
KVA |
Low pressure side |
High pressure side |
Measurement
Transformation ratio
|
Temperature rise ℃ |
impedance
Voltage
% |
No-load current
% |
weight
kg |
Dimensions
Length Х width Х height
mmХmmХmm |
|
Voltage
V |
Current
A |
VoltageKV |
Current
mA |
|
|
1.5/50 |
1.5 |
200 |
7.5 |
50 |
30 |
500:1 |
50 |
10 |
<4 |
30 |
200Х275Х640 |
|
3/50 |
3 |
200 |
15 |
50 |
60 |
500:1 |
50 |
10 |
<4 |
35 |
240Х300Х690 |
|
6/50 |
6 |
200 |
30 |
50 |
120 |
500:1 |
50 |
10 |
<4 |
40 |
250Х355Х710 |
|
10/50 |
10 |
200 |
50 |
50 |
200 |
500:1 |
50 |
10 |
<4 |
60 |
260Х375Х750 |
|
15/50 |
15 |
400 |
37.5 |
50 |
300 |
500:1 |
50 |
8 |
<4 |
70 |
270Х420Х800 |
|
20/50 |
20 |
400 |
50 |
50 |
400 |
500:1 |
50 |
8 |
<4 |
85 |
285Х440Х820 |
|
30/50 |
30 |
400 |
75 |
50 |
600 |
500:1 |
50 |
8 |
<4 |
100 |
295Х386Х840 |
|
50/50 |
50 |
400 |
125 |
50 |
1000 |
500:1 |
50 |
8 |
<4 |
120 |
320Х416Х910 |
|
10/100 |
10 |
200 |
50 |
100 |
100 |
1000:1 |
50 |
10 |
<4 |
65 |
350Х475Х1300 |
|
15/100 |
15 |
400 |
37.5 |
100 |
150 |
1000:1 |
50 |
8 |
<4 |
85 |
510Х390Х1320 |
|
20/100 |
20 |
400 |
50 |
100 |
200 |
1000:1 |
50 |
8 |
<4 |
100 |
540Х400Х1340 |
|
30/100 |
30 |
400 |
75 |
100 |
300 |
1000:1 |
50 |
8 |
<4 |
110 |
560Х410Х1360 |
|
50/100 |
50 |
400 |
125 |
100 |
500 |
1000:1 |
50 |
8 |
<4 |
125 |
600Х460Х1410 |
|
10/150 |
10 |
200 |
50 |
100 |
66.7 |
1500:1 |
50 |
10 |
<4 |
90 |
265Х380Х1750 |
|
15/150 |
15 |
400 |
37.5 |
150 |
100 |
1500:1 |
50 |
8 |
<4 |
100 |
510Х390Х1800 |
|
20/150 |
30 |
400 |
50 |
150 |
133.3 |
1500:1 |
50 |
8 |
<4 |
110 |
540Х415Х1800 |
|
30/150 |
30 |
400 |
75 |
150 |
200 |
1500:1 |
50 |
8 |
<4 |
125 |
560Х430Х1800 |
|
50/150 |
50 |
400 |
125 |
150 |
333.3 |
1500:1 |
50 |
8 |
<4 |
140 |
600Х450Х1800 |
|
20/200 |
20 |
400 |
50 |
200 |
100 |
2000:1 |
50 |
8 |
<4 |
140 |
600Х600Х1900 |
|
30/200 |
30 |
400 |
75 |
200 |
150 |
2000:1 |
50 |
8 |
<4 |
160 |
700Х700Х1900 |
|
50/200 |
50 |
400 |
125 |
200 |
250 |
2000:1 |
50 |
8 |
<4 |
200 |
750Х750Х2000 |
|
50/300 |
50 |
400 |
125 |
300 |
166 |
3000:1 |
50 |
8 |
<4 |
230 |
750Х750Х2300 |
|
100/300 |
100 |
400 |
250 |
300 |
333 |
3000:1 |
55 |
8 |
<4 |
300 |
850Х850Х2500 |
|
200/300 |
200 |
400 |
500 |
300 |
666 |
3000:1 |
55 |
8 |
<4 |
350 |
900Х900Х2600 |
|
300/300 |
300 |
400 |
750 |
300 |
1000 |
3000:1 |
55 |
8 |
<4 |
420 |
950Х950Х2700 |
|
Note: Can be customized according to users, non-standard products, the parameters are not in the scope of the table.
Features:
1. The gas-filled power frequency test transformer is small in size and light in weight (40%-65% lighter than the oil-immersed test transformer of the same grade)
2. Clean, no oil, no maintenance
3. It is not affected by the harsh weather environment, and the test can be done without standing still when transporting on site
4. The insulation strength is significantly higher than that of the oil-immersed test transformer, and the corona is extremely small