RC-100KV series AC and DC voltage divider is used in power system and electrical and electronic equipment manufacturing departments to measure power frequency AC high voltage and DC high voltage.
RC-100KV series AC and DC voltage divider is an instrument for on-site measurement. It can measure both DC high voltage and AC high voltage. The whole equipment is composed of a voltage divider and a measuring instrument. The voltage divider adopts a balanced equipotential shielding structure, and uses high-quality electronic components inside a completely sealed insulating cylinder, so that the entire device has the characteristics of accurate testing, good linearity, stable performance, reasonable structure, easy to carry, simple operation, intuitive display, etc. . This product complies with "DL/T846.1~2004 Technical Conditions of High Voltage Divider Measurement System".
Product nickname
High voltage tester, digital high voltage meter, high voltage measuring instrument, high voltage meter, high voltage digital meter, voltage divider, resistance-capacitance voltage divider, electrostatic voltmeter, high voltage divider, AC and DC voltage divider, AC and DC high voltage meter, AC DC high voltage divider, AC voltage divider, DC voltage divider, AC and DC dual-purpose high voltage test device, resistance-capacitance AC and DC voltage divider, AC and DC resistance-capacitance voltage divider, AC and DC digital voltage divider, kV Voltmeter, kilovoltmeter, FRC type AC and DC voltage divider
1. Voltage level: 50kV~400kV
2. Types: capacitive type, resistance type, resistance-capacitance type
3. Capacitive accuracy: AC: 1.5%, AC: 1.0%, AC: 0.5%
4. Resistance type accuracy: DC: 1.0%, DC: 0.5%, DC: 0.2%, DC: 0.1%
5. Accuracy of resistance-capacitance type: AC/DC: 1.5%/1.0%, 1.0%/0.5%, 0.5%/0.2%
6. Temperature coefficient of resistance: 200ppM, 100ppM, 50ppM, 25ppM
7. Capacitance temperature coefficient: -150ppM, -100ppM, -50ppM
8. Capacitor dielectric loss: the tangent value of the loss angle is not more than 10×10-4
9. Electric capacity: 8pF~1000pF
10. Working method:
(1) Continuous operation <30 minutes
(2) Continuous operation <60 minutes
(3) Continuous operation <8 hours
11. AC frequency: 30~300Hz (power frequency)
12. Environmental conditions:
Temperature: -25~40℃
Humidity: ≤85%
13. Dividing pressure ratio: 1000:1, 10000:1
14. Configuration table of conventional technical parameters of the instrument:
Model specifications Measuring voltage range
(kV) AC/DC voltage divider impedance
(MΩ) Dimensions (mm) Weight
Divider box
RC-50 AC~50 DC~70 320pF/650 Ф84×500 170×170×550 7
RC-100 AC~100 DC~140 160pF/1170 Ф84×650 170×170×720 10
RC-150 AC~150 DC~200 130pF/1690 Ф84×900 220×220×950 13
RC-200 AC~200 DC~250 100pF/2340 Ф90×1400 220×220×1450 18
RC-300 AC~300 DC~400 100pF/3380 Ф95×1750 260×260×1850 22
RC-400 AC~400 DC~500 75pF/4500 Ф142×2300 600×600×2350 30
1. High precision
Using precision high-voltage film capacitors and precision high-voltage glass glaze resistors, high input impedance, reduced test current, low power consumption, and improved measurement accuracy and stability of the instrument; the signal processing part uses high-performance OP for signal amplification and double integration Type AD sampling technology, four-and-a-half-digit liquid crystal display, with a maximum resolution of 0.001kV.
2. Good anti-interference performance
Adopt special shielding technology. The surface of the pressure equalizing ball of aluminum alloy material is smooth and shiny, which effectively improves the electric field distribution around the equalizing ball, prevents sharp discharges, and improves the anti-interference ability of the measurement data. Low-voltage display instrument adopts full gold
It is a closed structure and shielded. The high-voltage divider and the low-voltage display meter are connected by high-quality coaxial cables to reduce the impact of high voltage on the display value, so as to achieve high stability and high linearity
3. Safe and reliable
This instrument is composed of a high-voltage divider and a low-voltage display instrument. The high-voltage divider adopts American DuPont filling materials and is potted with a special process. It has a smaller structure, lighter weight, low internal partial discharge and high reliability. There is no oil leakage problem. The high-voltage divider and the low-voltage instrument are connected by coaxial cable when working, and the distance between the high and low voltage parts is relatively long, and the work is safe and reliable.
4. Simple operation
Adopt dial switch to switch between high and low voltage, AC and DC, which is convenient and quick. Four and a half LCDs directly display the measurement results, which is simple and intuitive. Bring convenience to on-site inspection work
5. Easy to carry
It adopts a portable structure, and the whole machine uses an aluminum alloy packing box as the casing, which can be easily disassembled and assembled. Small size, light weight, easy to carry, very convenient to use