24-Hour Hour Hotline:15388193573
WeChat
SF6 intelligent micro water meter
Product model:
Classification:SF6 intelligent micro water meter
Product time:2021-06-23
Describe:When the SF6 gas moisture tester is not used for a long time, there will be some air left in the test pipe
When the SF6 gas moisture tester is not used for a long time, there will be some air left in the test pipe and air chamber. Therefore, in the first test, the high humidity gas in it will affect its test speed, because the tested SF6 The moisture in the air needs to be taken away before the gas reaches saturation. So we will find that when testing the second SF6 electrical equipment and the measurement speed will be very fast (3-5 minutes).
If you need to make a measurement in high temperature weather, we recommend that you try to arrange the measurement time in the morning when the temperature is low, because the higher temperature will affect the accuracy of the measurement.
Reference Standard: Electric Power Industry Standard DL/T506-2007 "Method for Measuring Humidity of Insulating Gas in Electrical Equipment of Sulfur Hexafluoride"
Requirements for measuring ambient temperature and humidity
Ambient temperature: 5℃~35℃ (as far as possible to measure between 10℃~30℃)