Main Specifications
AC measurement
·Voltage range (V): 6.25, 12.5, 25, 50, 100, 200, 400, 800, fully automatic switching, maximum 1000V;
·Current range (A): 0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100, fully automatic switching;
·Voltage, current and power measurement accuracy ±(0.012%RD+0.008%RG);
·The accuracy of electric energy measurement is ±0.02%;
·Standard pulse output ≤2MHz;
·Frequency measurement range 45~65Hz;
·The frequency measurement accuracy is 0.01Hz;
·Phase measurement error ±0.02°;
·Power factor measurement error ±0.0001;
·Harmonic and distortion measurement
The harmonic order is 31 times;
Harmonic measurement error ±(5%RD+0.05%) RD is the harmonic content reading;
Distortion measurement error ±(5%RD+0.05%) RD is the distortion reading.
DC measurement (option)
·Voltage range (V): 50, 100, 200, 400, 800, automatic switching;
·Current range (A): 0.1, 0.3, 1, 3, 10, 30;
·Voltage and current measurement accuracy ±(0.03%RD+0.02%RG).
Transmitter measurement
·DC voltage ±1, ±5, ±10, ±20V 0.02%;
·DC current ±1, ±2.5, ±5, ±10, ±20mA 0.02%;
·Ripple measurement error is 1%.
Working power: Single-phase 220V±10%, 50Hz±5%.
Use environment temperature 20℃±10℃, relative humidity ≤85%RH.
Volume and weight 440×360×155mm3, about 10kg.